Showgear PowerCore 32.12p Power Distributor
Twelve rear Power Pro True outlets have individually protected RCBO circuits. The front Schuko socket connects to circuit 12 as an alternative connection for that circuit.
Each 16 A RCBO combines residual-current and overcurrent protection. LEDs indicate output power status, and a 3.14-inch LCD provides access to electrical measurements.
The meter shows phase voltage, current, power, energy and power-quality data. MdbuS communication supports up to six units on one link with an optional PowerCore Server.
The 32 A three-phase input includes an attached 1 m CEE cable. The black aluminium and metal enclosure occupies 3 U, with a CNC-milled front panel and PCE connectors.
Main Features
- Power Pro True outlets serve equipment with matching power cables.
- Twelve RCBOs provide separate output-circuit protection.
- The front Schuko socket offers an alternative connection to circuit 12.
- LEDs show which outputs are receiving power.
- The LCD meter displays phase loads and electrical parameters.
- Power-quality monitoring includes THD, harmonics and phase imbalance.
- MdbuS connections support remote monitoring through an optional server.
- The USB-C output supplies 5 V to compatible equipment.
Technical Specifications
- Function: Three-phase power distribution
- Rated Current: 32 A per phase
- Power Input: CEE 5-pin (3P+N+PE), 32 A; 400 V AC, 50 Hz; attached 1 m cable
- Power Outputs: 12 × rear Power Pro True plus 1 front Schuko Type F, 16 A each
- Protection: 12 × RCBO, 16 A, C curve, Type A, 30 mA, 2-pole
- Front Socket Circuit: Shared with rear output 12; 12 independent circuits
- USB Power: USB-C, 5 V
- Data Connections: 3-pin XLR input and output; MdbuS
- Remote Monitoring: Optional PowerCore Server; up to 6 devices per link
- Meter Readouts: Phase and line voltage, phase and neutral current, active/reactive/apparent power, power factor, frequency and temperature
- Energy Metering: Total and per-phase energy, import/export counters, date and runtime
- Power Quality: Voltage/current THD, harmonics 2–31 and phase imbalance; minimum/maximum voltage history
- Circuit Indicators: 12 LEDs: green for power present, red for no power
- Internal Power Consumption: 7.5 W; internal 1 A fuse
- Meter Settings: Must be configured according to the manual before use
- Potential Equalisation: Dedicated ground lug; optional grounding cable
- Display and Controls: 3.14-inch LCD and 5 control buttons
- Dimensions (W × H × D): 483 × 139 × 344 mm
- Weight: 12.4 kg
- Rack Mounting: 19-inch, 3 U
- Housing: Aluminium and metal, black; CNC-milled front panel and PCE connectors
- Ingress Protection: IP20, indoor use only
- Operating Temperature: −5 to 40 °C
- Intended Use: Professional indoor equipment; not for household use
What’s Included
- 1 × Showgear PowerCore 32.12p Power Distributor
- Attached 1 m input cable with CEE plug
The PowerCore Server and potential-equalisation cables are sold separately. Configure the meter according to the manual before use. Do not use RCBOs as load switches.
Who Is It For
For indoor stage and event equipment using Power Pro True cables and a 32 A three-phase supply. Having twelve output circuits does not increase the input capacity.
Can’t find the Showgear product you are looking for?
Contact us: info@stageiq.lt or +370 636 55536.