{"product_id":"showgear-powercore-63-4c","title":"Showgear PowerCore 63.4c Power Distributor","description":"\u003ch2\u003eShowgear PowerCore 63.4c Power Distributor\u003c\/h2\u003e\n\u003cp\u003eFour rear 32 A CEE outlets distribute three-phase power from a 63 A input. Each output has its own four-pole RCBO.\u003c\/p\u003e\n\u003cp\u003eThe RCBOs combine residual-current and overcurrent protection. Twelve LEDs show the phase status of the four outputs, with three indicators per output.\u003c\/p\u003e\n\u003cp\u003eA 3.14-inch LCD displays voltage, current, power, energy and power-quality measurements. MdbuS connections support monitoring up to six units on one link through an optional PowerCore Server.\u003c\/p\u003e\n\u003cp\u003eThe black 4 U enclosure features a CNC-milled aluminium front panel and PCE connectors. A rear potential-equalisation lug and front 5 V USB-C power output provide additional connections.\u003c\/p\u003e\n\u003ch3\u003eMain Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFour five-pin CEE outlets carry 3P+N+PE power.\u003c\/li\u003e\n\u003cli\u003eA separate four-pole RCBO protects each 32 A output.\u003c\/li\u003e\n\u003cli\u003eThe 63 A input distributes three-phase power to multiple systems.\u003c\/li\u003e\n\u003cli\u003eThree LEDs per output indicate the state of its individual phases.\u003c\/li\u003e\n\u003cli\u003eThe LCD provides local load and supply measurements.\u003c\/li\u003e\n\u003cli\u003eTHD, harmonics and imbalance data support power-quality checks.\u003c\/li\u003e\n\u003cli\u003eMdbuS communication enables remote monitoring with an optional server.\u003c\/li\u003e\n\u003cli\u003eThe 4 U enclosure fits a standard 19-inch rack.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunction:\u003c\/strong\u003e Three-phase power distribution\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current:\u003c\/strong\u003e 63 A per phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Input:\u003c\/strong\u003e CEE 5-pin (3P+N+PE), 63 A; 400 V AC, 50 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Outputs:\u003c\/strong\u003e 4 × CEE 5-pin (3P+N+PE), 32 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection:\u003c\/strong\u003e 4 × RCBO, 32 A, C curve, Type A, 30 mA, 4-pole\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUSB Power:\u003c\/strong\u003e USB-C, 5 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Connections:\u003c\/strong\u003e 3-pin XLR input and output; MdbuS\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote Monitoring:\u003c\/strong\u003e Optional PowerCore Server; up to 6 devices per link\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeter Readouts:\u003c\/strong\u003e Phase and line voltage, phase and neutral current, active\/reactive\/apparent power, power factor, frequency and temperature\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnergy Metering:\u003c\/strong\u003e Total and per-phase energy, import\/export counters, date and runtime\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Quality:\u003c\/strong\u003e Voltage\/current THD, harmonics 2–31 and phase imbalance; minimum\/maximum voltage history\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCircuit Indicators:\u003c\/strong\u003e 12 LEDs: 3 per three-phase output; green for power present, red for no power\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInternal Power Consumption:\u003c\/strong\u003e 7.5 W; internal 1 A fuse\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeter Settings:\u003c\/strong\u003e Must be configured according to the manual before use\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePotential Equalisation:\u003c\/strong\u003e Dedicated ground lug; optional grounding cable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay and Controls:\u003c\/strong\u003e 3.14-inch LCD and 5 control buttons\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (W × H × D):\u003c\/strong\u003e 483 × 183 × 411 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 13.8 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Mounting:\u003c\/strong\u003e 19-inch, 4 U\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing:\u003c\/strong\u003e Aluminium and metal, black; CNC-milled front panel and PCE connectors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIngress Protection:\u003c\/strong\u003e IP20, indoor use only\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e −5 to 40 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntended Use:\u003c\/strong\u003e Professional indoor equipment; not for household use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhat’s Included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 × Showgear PowerCore 63.4c Power Distributor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe PowerCore Server and potential-equalisation cables are sold separately. Configure the meter according to the manual before use. Do not use RCBOs as load switches.\u003c\/p\u003e\n\u003ch3\u003eWho Is It For\u003c\/h3\u003e\n\u003cp\u003eFor indoor event distribution systems that need four 32 A three-phase CEE branches from one 63 A input. The combined connected load must not exceed 63 A on any input phase.\u003c\/p\u003e\n\u003ch3\u003eCan’t find the Showgear product you are looking for?\u003c\/h3\u003e\n\u003cp\u003eContact us: info@stageiq.lt or +370 636 55536.\u003c\/p\u003e","brand":"Showgear","offers":[{"title":"Default Title","offer_id":57014193422722,"sku":"E623030","price":1299.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0931\/9736\/9730\/files\/showgear-powercore-63.4c-01.jpg?v=1793693545","url":"https:\/\/stageiq.lt\/en\/products\/showgear-powercore-63-4c","provider":"STAGE IQ","version":"1.0","type":"link"}